Curtain Wall Glass Replacement & Façade Failure Investigation
Capability Statement
Introduction
My name is Adam Punin. I am 57 years old and the Director of Master Glass Facades in Sydney, with more than 40 years of experience in the glazing industry. Master Glass Facades was previously known as Adam’s Express Glazing, a family business opened by my grandfather in 1954. My grandfather started the business; my father continued it, and I was brought into the trade from a young age, beginning work with glass around the age of 10 before starting my apprenticeship at 14.
Express Glazing, a family business opened by my grandfather in 1954. My grandfather started the business; my father continued it, and I was brought into the trade from a young age, beginning work with glass around the age of 10 before starting my apprenticeship at 14.
Because I began cutting and processing glass at such a young age, I developed a detailed understanding of how glass behaves. I have worked with glass ranging from approximately 2mm through to 30mm thickness and have been involved in fabrication, installation and investigation of glazing systems throughout my career.
Professional Record
Master Glass Facades has never had an insurance claim made against the company, and we have not experienced failures of glass panels supplied and installed by our team. Our approach focuses on correct glass specification, careful installation, and ensuring replacement panels are engineered correctly so failures do not occur again.
Curtain Wall & Glass Failure Investigation
• Thermal stress fractures
• Nickel sulphide inclusions in toughened glass
• Edge damage during fabrication or installation
• Incorrect setting block placement
• Frame deflection or structural building movement
• Pressure equalisation or curtain wall drainage failure
• Seal failure in insulated (double-glazed) units
• Laminated glass interlayer failures
In many situations, our work involves identifying the real cause of failure before replacement occurs. The key issue is not simply replacing the glass, but ensuring it is redesigned correctly so the problem does not occur again.
Double-Glazed Unit Failure Investigation
• Seal failure leading to condensation between panes
• Moisture ingress into the cavity
• Spacer or desiccant failure
• Thermal stress caused by façade design or shading
• Nickel sulphide inclusion breakage in toughened glass
• Incorrect glass selection for the façade system
Correct Replacement Design. When replacing curtain wall panels, we often redesign the glazing specification where required. For example, where toughened glass was originally used on both faces, replacement panels may be redesigned using heat-strengthened glass and argon filled insulated glass units with laminated safety glass internally where required.
Glass Roofs & Structural Glazing
We also investigate failures in structural glass roofs and skylights. In certain conditions a ‘blanket effect’ can occur where heat build-up between glass layers creates thermal stress that may cause glass breakage.
Glass Balustrades
When replacing frameless glass balustrades originally constructed with monolithic toughened glass, we commonly upgrade the glazing to toughened laminated safety glass to ensure improved safety performance.
System Development & Industry Innovations
• Design of a thermally broken aluminium window system used on one of the first 6–7 star energy rated buildings in NSW
• Development of specialised glazing putty for steel window systems
• Design of custom glazing blocks and Santoprene rubber glazing components
• Modification of the Capral 889 system allowing internal sliding door configurations
Builders & Contractors Worked With
• Buildcorp
• Abbey Group
• Barclay Mowlam
• St Hilliers
• Walters Group
• Austral Interiors
• Brighton Interiors
Façade Contractors & Manufacturers
• Empire Facades
• Facade Innovations
• Onsite Constructions
• Arc Systems Fabrication
• G. James
• Architectural Glass Projects
Insurance Companies
• GIO
• NRMA
• QBE
• Allianz• Suncorp
Major Project Experience
• Hilton Hotel – largest panels in the Southern Hemisphere at the time
• Jamison Street Hotel – specialist glazing works
• Meriton Apartments Head Office – structural steel glazed roof
• Campbelltown Hospital – curtain wall manufactured by our team
• Harbour Bridge lift enclosures – specialist glazing works
• Allianz Stadium – specialist glazing involvement
• Barangaroo – façade and glazing related works
Adam Punin
Director – Master Glass Facades | Sydney NSW